[PATCH] Fine tune the time conversion to eliminate conversion errors.
From: George Anzinger <george@mvista.com>
The time conversion code is erroring on the side of a bit too small. The
attached patch forces any error to be on the high side. The current code will
convert 1 nanosecond to zero jiffies (standard says that should be 1). It also
is around 1 nanosecond late on each roll to the next jiffie.
I have done some error checks with this patch applied and get the following
errors in PPB ( Parts Per Billion):