can: m_can: tag current CAN FD controllers as non-ISO
authorOliver Hartkopp <socketcan@hartkopp.net>
Mon, 5 Jan 2015 18:47:43 +0000 (19:47 +0100)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Fri, 30 Jan 2015 01:40:42 +0000 (17:40 -0800)
commitb47d1db630f022bc88f1085d831ec4aee71a25e6
treed216db762b3d0dc1df1ad38a7d344b3389a3af6b
parent96bfa3859e9c40f53ecc79ea3c23dbb72188a56b
can: m_can: tag current CAN FD controllers as non-ISO

commit 6cfda7fbebe8a4fd33ea5722fa0212f98f643c35 upstream.

During the CAN FD standardization process within the ISO it turned out that
the failure detection capability has to be improved.

The CAN in Automation organization (CiA) defined the already implemented CAN
FD controllers as 'non-ISO' and the upcoming improved CAN FD controllers as
'ISO' compliant. See at http://www.can-cia.com/index.php?id=1937

Finally there will be three types of CAN FD controllers in the future:

1. ISO compliant (fixed)
2. non-ISO compliant (fixed, like the M_CAN IP v3.0.1 in m_can.c)
3. ISO/non-ISO CAN FD controllers (switchable, like the PEAK USB FD)

So the current M_CAN driver for the M_CAN IP v3.0.1 has to expose its non-ISO
implementation by setting the CAN_CTRLMODE_FD_NON_ISO ctrlmode at startup.
As this bit cannot be switched at configuration time CAN_CTRLMODE_FD_NON_ISO
must not be set in ctrlmode_supported of the current M_CAN driver.

Signed-off-by: Oliver Hartkopp <socketcan@hartkopp.net>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/net/can/m_can/m_can.c
include/uapi/linux/can/netlink.h