- RAID5 data: without the series about half the replaces hang; with
thread_pool=64 the pool limit is gone and patch 2's deadlock appears
instead (counter 2, two readers sleeping under the checksum lookup).
- With the series, none of 48 replaces hung, nor 24 with
+ With the series, none of 72 replaces hung, nor 48 with
thread_pool=64.
- RAID6 data with the P strips corrupted, so a rebuild from P fails its
checksum and read repair goes on to rebuild from Q: without the series
the first replace hangs, all 8 btrfs-rmw workers waiting to submit the
- repair read. With the series, none of 48 replaces hung.
+ repair read. With the series, none of 72 replaces hung.
- RAID1 data with one mirror corrupted and a present device replaced
- (repairs in btrfs-endio): none of 48 hung with the series; this did not
+ (repairs in btrfs-endio): none of 72 hung with the series; this did not
hang without it either (0 of 24).
Each hang was confirmed with drgn, matching the counter against the
bios held behind the waiting workers. The device replace, scrub and