]> git.hungrycats.org Git - linux/commitdiff
thermal: armada: Update Armada 380 thermal sensor coefficients
authorNadav Haklai <nadavh@marvell.com>
Wed, 15 Apr 2015 17:08:08 +0000 (19:08 +0200)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Sat, 6 Jun 2015 15:21:06 +0000 (08:21 -0700)
commit efa86858e1d8970411a140fa1e0c4dd18a8f2a89 upstream.

Improve the Armada 380 thermal sensor accuracy by using updated formula.
The updated formula is:
Temperature[C degrees] = 0.4761 * tsen_vsen_out - 279.1

Signed-off-by: Nadav Haklai <nadavh@marvell.com>
Signed-off-by: Gregory CLEMENT <gregory.clement@free-electrons.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/thermal/armada_thermal.c

index c2556cf5186bc75b71870ed6a304fda430b8521b..01255fd65135949ce78b7f94fde7bccc196ac75c 100644 (file)
@@ -224,9 +224,9 @@ static const struct armada_thermal_data armada380_data = {
        .is_valid_shift = 10,
        .temp_shift = 0,
        .temp_mask = 0x3ff,
-       .coef_b = 1169498786UL,
-       .coef_m = 2000000UL,
-       .coef_div = 4289,
+       .coef_b = 2931108200UL,
+       .coef_m = 5000000UL,
+       .coef_div = 10502,
        .inverted = true,
 };